Job Location: Paint Department at Skyjack, Glendale, AZ. Analyst: Filling lacquer thinner P20 from the main drum into metal nonflammable sub container. (1910.106(d)). Date:12/7/2015
Task Description: 1.Check container labeling and match with labeling with main drum, then open the cup or cover of the sub container. 2.Place the container under the hand pump hose that is attached to the main drum. 3. Attach the grounding cable into the container as well as the drum. 4. Start pumping to the designated container level. 5. disconnected the grounding cable. Close the cup
…show more content…
Make sure no source of ignite around the area and the area well vented and clean out any spill (Follow SDS Instruction for spilling).
Hazard Description: Flammable hazard, Health hazard,
Hazard Controls: Use the grounding cable during transferring process to prevent and igniting spark, use proper PPE (Safety glass, Face shield, Plastic apron, Proper respray. Hazardous Materials (Flammable liquids), n.d.).

Job Location: Assembly department at Skyjack, Glendale, AZ. Analyst: Changing Abrasion wheel for bench grinder. (1910.215). Date: 12/7/2015
Task Description: 1. Turn off the grinder and turn off the circuit breaker and LO/TO the grinder 1910.147. (Let cool down if it is hot). 2. Remove the work rest and tongue guard from wheels. 3. Unscrew the wheel bolts, then remove the defecting wheel. 4. Check the new wheel speciation and confirm the wheel is a free from crake and or not broken (conduct ring test) and place it back inside the Spidle